Fluke Ti400

 Fluke Ti400
608 003 .

.

. , , Fluke Ti400, .

" ". , . , .

, .

Fluke Ti400 LaserSharp, . . . . , - . , 20 . LaserSharp . , . , .

.

, 5 CNX. , .

, .

Fluke SmartView  .

* , SmartView, .


  • Fluke IR-Fusion AutoBlend
  • , Apple iPhone iPad
  • Fluke CNX*
  • ,
  • 640x480
  • , , IR-PhotoNotes
  • , (USB HDMI)
  • ,
  • 1200 C
  • 5 .
  • SmartView SmartView

( 10 C)

-20 C +1200 C 
( -4 F +2192 F)

2 C 2 % ( 25 C, )

( )

9  60 ,

, , 320 x 240

(NETD)

≤ 0,05 C 30 C (50 K)

, .

76,800

7,5 14  ()

, 5,0

24 x 17

(IFOV)

1,31 

15  6 )

,

12 x 9

(IFOV)

0,65 

45  ( 18 )

,

46 x 34

(IFOV)

2,62 

15  6 )

LaserSharp

" ", -, , , , , ,

Ultra Contrast ()

" " Ultra, - Ultra, Ultra, Ultra, Ultra, Ultra, Ultra, Ultra

( )

2,0 C (3,6 F)

( )

3,0  C (5,4  F)

IR-Fusion

Picture-In-Picture (PIP - )

AutoBlend

( )

, , ( )

,

,

Micro SD, -, USB, USB

(.bmp) (.jpeg), (.is2)

(.bmp .jpg)

, SmartView

BMP, DIB, GIF, JPE, JFIF, JPEG, JPG, PNG, TIF TIFF

- 60 ,

IR-PhotoNotes

Wi-Fi

, , iPhone, iPad WiFi LAN*

*

*

USB HDMI-

CNX*

*

( )*

( )

-10 C +50 C ( 14 F 122 F)

-20 C +50 C

10 % 95 %

()

- VGA (640x480) 8,9 (3,5 )

(C/F),

/

,

-- .

SmartView SmartView

- , ,

4 ( 50% - )

- 2,5

( 110 220 . , 50/60 ) ( ), . . (12 ).

( 110 220 . , 50/60 ), . .

UL 61010-1:2012 CAN/CSA-C22.2 No.61010-1-12 IEC 61010-1 3 (2010)

EN 61326-1:2006 IEC 61326-1:2005

C Tick

IEC/EN 61326-1

US FCC

CFR 47, 15, , B

.

0,03 g2/ (3,8 . ), 2.5g IEC 68-2-6

:

25 G, IEC 68-2-29

2 (6,5 )

( x x )

27,7 x 12,2 x 16,7 (10,9 x 4,8 x 6,5 )

( )

1,04 (2,3 )

IP54 ( )

( )

, , , , (), (), , , , , , , , , , ,