Fluke TiS60

  Fluke TiS60
370 088 .

2,5 ¹

     2,5
  • 260x195 
  • ,  
  • D:S 417:1 
  • " " 5 IR-Fusion 
  • - 3,5 320x240 33% - 3,0  
  •  

  • 4 4 Micro SD 
  • Micro SD 4  
  • IR-PhotoNotes ² 

""

  • "" -  
¹ Ti1xx
² Bluetooth /

  •  
  • 260x195 (50 700 ) 
  • D:S 417:1 
  • : -20 C +550 C ( -4 F 1022 F ) 
  • IR-Fusion PIP , ,  
  • 3,5 , - 320x240 
  • 5  
  • "" - "" ,  
  • 4 4 Micro SD

(IFOV)

2,4

260x195

35,7 × 26,8

417:1

IR-Fusion

AutoBlend

5 (0%, 25%, 50%, 75%, 100%)

Picture-In-Picture (PIP )

5 (0%, 25%, 50%, 75%, 100%)

, 0,45 (1,5 )

3,5 ( ), - 320x240

(NETD)

≤0,08 C 30 C (80 K)

( -10 C)

-20 C +550 C ( -4 F 1022 F)

( )

2,5 C

( )

5 C

( )

5

9  

SD-

4 Micro SD 4

,

,

(.bmp) (.jpeg) (.is2);
(.bmp, .jpg)

SmartView , Fluke Connect ( )

, SmartView

BMP, DIB, GIF, JPE, JFIF, JPEG, JPG, PNG, TIF TIFF

, Bluetooth ( )

IR-PhotoNotes

(3 )

(MPEG .AVI) (.IS3)

( )

(, )

- "" ,

 

2,5

( 100 240 . , 50/60 ),

2 C 2% ( 25  C, )

( )

8: " ", -, , , , , ,

Ultra Contrast

8: " " Ultra, - Ultra, Ultra, Ultra, Ultra, Ultra, Ultra, Ultra

( )

, ,

7,5 14

-10 C +50 C ( 14 F 122 F)

20 C +50 C ( 4 F 122 F)

10 % 95 % ( )

:

3

- . --

EN 61010-1: , 2, EN 60825-1: 2, EN 60529, EN 62133 ( )

EN 61326-1:2006, EN 55011: A, EN 61000-4-2, EN 61000-4-3

C Tick

IEC/EN 61326-1

US FCC

EN61326-1; FCC 5, EN 55011: A, EN 61000-4-2, EN 61000-4-3

-

2G, IEC 68-2-6 25G, IEC 68-2-29

, 2 (6,5 )

( ×  × )

26,7 x 10,1 x 14,5 (10,5 x 4,0 x 5,7 )

( )

0,72 (1,6 ), 0,77 (1,7 )

IP54 ( )

( )

, , , , (), (), , , , , , , , , , ,